Home Up

LD160

VEHICLE LOOP DETECTOR

The LD160 is a single channel inductive loop detector. The LD160 is compatible with most single channel detectors on the market and is easy to set-up and install.

Typical applications in the traffic environment are traffic control (traffic lights), toll systems and vehicle counting.

Standard features of the detector are :

· Reset Switch.

The reset switch enables the detector to be manually reset during commissioning and testing. This results in the detector re-tuning the sensing loop and becoming ready for vehicle detection.

 

· Switch selectable Sensitivity.

Eight sensitivity settings are available on the switches to allow flexibility in configuration and application.

1 High 0.01% 5   0.2%
2   0.02% 6   0.5%
3   0.05% 7   1%
4   0.1% 8 Low 2%

· Switch selectable Frequency.

Two frequency settings are available to prevent cross-talk between adjacent loops.

· Fault Relay feature.

The Fault relay is activated when a fault has occurred on the loop.

TECHNICAL DATA

1. POWER REQUIREMENT:

LD160 - 220VAC (+/- 15% ) 50Hz.
LD161 - 110VAC (+/- 15%) 60Hz.
LD162 - 12/24VAC/DC (+/- 15%).

2. PRESENCE RELAY OUTPUT: This output has both a normally open and normally closed relay contact rated at 0.5A/220VAC.

3. FAULT RELAY OUTPUT: This output is a normally open relay contact rated at 0.5A/220VAC.

4. INDICATORS: LED indicators show: Power, Detect state and Loop Fault.

5. DETECTOR TUNING RANGE: 15 - 1500 uH.

6. FREQUENCY: Two step adjustable.

7. PROTECTION: Loop isolation transformer, zener diode and MOV protection on loop input.

8. CONNECTOR: 11 Pin Connector on rear of unit.

9. DIMENSIONS: 75mm (HIGH) X 40mm (WIDE) X 75mm (DEEP)

10. OPERATING TEMPERATURE: -40°C to +80°C

11. STORAGE TEMPERATURE: -40°C to +85°C

12. HUMIDITY: up to 95% non condensing

13. Complies with EMC Directive 89/336/EEC and Low Voltage Equipment Directive 73/23/EEC.

 

 

Send mail to proconel@proconel.com with questions or comments about this web site.